Skip to content

Drip, sprinkler and irrigation automation · Chennai & Bengaluru

Water level & tanks

Wireless single tank controllers and wireless switches

Greenly wireless tank controllers send the tank level to the pump by radio, so there is no cable to lay between the tank and the motor. GSM models add call and SMS control with regional-language voice responses.

Wireless single tank controllers and wireless switches
Models
1010S and 3010 GSM WLC with 1000 GSM BOD
Link
Wireless level Tx/Rx
Remote
GSM voice and SMS
Extras
Wireless switch Tx and Rx

Range

Models (4)

Compare features and ratings, then ask for the price and datasheet of the model that fits.

Wireless 1010S GSM BOD with 1000 GSM BOD

Greenly · Wireless tank controllers

Wireless 1010S GSM BOD with 1000 GSM BOD

Suitable for
  • All types of Single Phase Pumps

Features

  • Regional Languages Select Option for Voice response
  • GSM(T/R) based wireless level Transmitter / Receiver
  • Top Tank Level Control
  • Bottom Tank Level Control
  • Low / High Voltage Cut-off
  • Dry Run / Over Load Protection
  • Dry Run Restart Timer Facility / Cyclic Timer Facility, RTC Timer
  • Adjustable Voltage & Current Settings

Technical specifications

ParameterRating
Operating Voltage (AC)1∅ – 150V to 270V
Operating Voltage for float SensorMin 12V DC
Calibration accuracy+/- 5%
DimensionL 150 X W 80 X H 350 mm
Relay Load1∅ – 20 Amp
Direct Load ***1∅ – 2 HP
Indirect Load ***Any Size
Wireless 3010 GSM WLC BOD with 1000 GSM BOD

Greenly · Wireless tank controllers

Wireless 3010 GSM WLC BOD with 1000 GSM BOD

Suitable for
  • All types of Single Phase Pumps

Features

  • Regional Languages Select Option for Voice response
  • GSM(T/R) based wireless level Transmitter / Receiver
  • Top Tank Level Control
  • Bottom Tank Level Control
  • Low / High Voltage Cut-off
  • Dry Run / Over Load Protection
  • Dry Run Restart Timer Facility / Cyclic Timer Facility, RTC Timer
  • Adjustable Voltage & Current Settings

Technical specifications

ParameterRating
Operating Voltage (AC)3∅ – 300V to 470V
Operating Voltage for float SensorMin 12V to Max 30V DC
Calibration accuracy+/- 5%
DimensionL 150 X W 80 X H 350 mm
Relay Load3∅ – 10 Amp
Indirect Load ***Any Size
Wireless Switch Transmitter – SSN

Greenly · Wireless tank controllers

Wireless Switch Transmitter – SSN

Features

  • Elimination from tank to water level controller
  • User-friendly LED indication
  • It can be connected with all models of the Greenly water level controller
  • Water pump controller since the water level in upper tank using float technology
  • Switch off the water pump when the upper tank is full / when the sump is empty
  • Switch on the water pump when the upper tank is empty and the sump has enough water
  • Switch off the water pump during the dry running mode
  • Magnetic tape low-level high-level operation

Technical specifications

ParameterRating
Operating Voltage (AC)1∅ – 150V to 270V
Operating Voltage for float SensorMin 12V DC
DimensionL 130 X W 90 X H 70 mm
Relay Load1∅ – 20 Amp
Direct Load ***1∅ – 2 HP
Indirect Load ***Any Size
Wireless Switch Receiver – SSN

Greenly · Wireless tank controllers

Wireless Switch Receiver – SSN

Features

  • Elimination from tank to water level controller
  • User-friendly LED indication
  • It can be connected with all models of the Greenly water level controller
  • Water pump controller since the water level in upper tank using float technology
  • Switch off the water pump when the upper tank is full / when the sump is empty
  • Switch on the water pump when the upper tank is empty and the sump has enough water
  • Switch off the water pump during the dry running mode
  • Magnetic tape low-level high-level operation

Technical specifications

ParameterRating
Operating Voltage (AC)1∅ – 150V to 270V
Operating Voltage for float SensorMin 12V DC
DimensionL 130 X W 90 X H 70 mm
Indirect Load ***Any Size

Selection guide

What to check before you choose

Have these details ready. They decide the right system and model, and they speed up your quotation.

  • Number of tanks and sumps, and whether they are in the same building
  • Distance between the tank and the pump, and whether a cable can be run
  • Single-phase or three-phase pump, and its rating
  • Whether you need only an indicator, an alarm, or full automatic pump control
  • Whether you want alerts or control on your phone

From enquiry to handover

How we work

  1. 01

    Share your requirement

    Tell us the crop or site, the area, the water source and the pump you use today. A phone photo of the pump panel helps.

  2. 02

    Survey and design

    We check the water source, pressure, power supply and layout, then size the system and the controls.

  3. 03

    Itemised quotation

    You receive a quotation with every component, model and quantity listed, so you can compare like for like.

  4. 04

    Supply and installation

    Our team supplies and installs the system, wires the controllers and tests every zone and alarm.

  5. 05

    Training and handover

    We show you how to run, schedule and maintain the system, including the mobile app where it is used.

  6. 06

    Service support

    Spares, repairs and upgrades are available from our Chennai and Bengaluru offices.

FAQs

Frequently asked questions

Still have a question? Call +91 86100 00128 or contact us.

Can one tank controller serve several buildings?

For several tanks or buildings use the wireless multi-tank controller, which handles more than one tank with priorities.

How does an automatic water level controller work?

Sensors in the overhead tank and the sump tell the controller the water level. It starts the pump when the overhead tank is low and the sump has water, and stops it when the tank is full or the sump runs dry.

Do I need to run a cable from the tank to the pump room?

Not with the wireless models. A transmitter at the tank sends the level to a receiver at the pump, which is useful in apartments, factories and farms where cabling is difficult.

Which sensor type should I use?

Float switches are simple and economical. Magnetic and screw-type sensors are sealed, resist scaling and corrosion, and suit tanks where floats tangle or stick. We recommend the type after checking the tank.

Will this reduce my electricity and water use?

It stops overflow and dry running, which are the two common sources of waste, and keeps the pump from running longer than needed. Actual savings depend on how the tank was being filled before.

Explore further

Related solutions and products

From requirement to quotation

Tell us about your farm or site

Share the crop or site, the area, the water source and your pump. We reply with the right system and an itemised quotation.

Talk to an irrigation engineer

Not sure which system fits your farm or site?